Share:


OSRAM ELEMENT 180/220-240/24 G2

OSRAM ELEMENT 180/220-240/24 G2

  • 180/220-240/24 G2

Benefits
  • Well design for Flex and Signage
  • High efficiency up to 91%
  • Class II design for wide application 
  • Excellent price/quality/ watt ratio
Areas of application
  • Hospitality - decorative lighting, night light
  • Restaurants - decorative lighting
  • Shops - decorative lighting, shelf lighting
  • Residential - cove lighting, under cabinet lighting
Product features
  • 24V constant output voltage
  • Output power up to 60W
  • SELV
  • Main voltage 220-240V
  • High efficiency up to 89%
  • PF >0.95
  • Screw terminal
  • Cable clamp intergrated
  • Over load protection
  • Over temperature protection
  • Short circuit protection
  • Suitable for Class I/II luminaires, built-in & independent installation
  • Wide Ta range -20 - +50°C
  • 30000 h @ Tc max
  • 3Y guarantee
Electrical Specifications
INPUT
  • Nominal voltage : 220 – 240 V
  • Mains frequency : 50 / 60 Hz
  • Input voltage AC : 198 – 264 V
  • Maximum voltage : 280 Vac (2 h maximum, unit might not operate in this abnormal
  • condition)
  • Nominal current : 0.9 A (At 230 Vac)
  • Total Harmonic Distortion (THD) : < 15 % (Full load, 230 Vac, 50 Hz / 60 Hz)
  • Power factor λ : 0,95 (Typical, Full load, 230 Vac, 50 Hz / 60 Hz)
  • ECG Efficiency : 91 % (Typical, Full load, 230Vac, 50Hz)
  • Power loss : 17.8 W (Full load, 230 Vac, 50Hz / 60Hz)
  • Power loss in no load condition : <1 W (230Vac, 50Hz typical)
  • Protection class : II (Suitable for safety class I and II luminaires)
  • Suitable for fixtures with prot. Class : I / II
  • Inrush current : <40 Apk / 765 us
  • Max ECG no. on circuit breaker 10A : B: / C:5
  • Max ECG no. on circuit breaker 16A : B:5 / C:9
  • Max ECG no. on circuit breaker 25A : B:8 / C:14
OUTPUT
  • Nominal output voltage : 24 V
  • Voltage accuracy : +/- 3 %
  • Voltage ripple : < 3 % (Ripple / average @ 100 Hz; Full load)
  • Nominal output power : 180 W
  • Maximum power : 180 W (LED output)
  • Capacitive load : 20 uF/A
  • Galvanic isolation : SELV
  • U-OUT : 25 V
ENVIRONMENT
  • Ambient temperature range : -20 - +50 °C
  • Max. temperature at tc test point operation : 90 °C (Measured on tc point indicated of the prod label, ta not exceeded)
  • Max. case temp. in fault condition : 110 °C
  • Storage temperature range : -40 - +85 °C
  • Permitted rel. humidity during : 5 – 85 % (Not condensing)
  • Surge capability (L/N) : 1 kV (L/N acc to. EN 61547)
  • Environmental rating : Indoor
  • IP protection class : IP 20
  • Mains switching cycles : > 50’000
  • Expected lifetime : 30’000 (At tc max with 10% failure rate) / 50’000 h (At tc-10oC with 10% failure rate)
  • No-load proof : Yes
  • Overheating protection : Yes (Automatically restart)
  • Overload protection : Yes (Automatically restart)
  • Short-circuit protection : Yes (Automatically restart)
  • Dimension : 300x40x31 mm (L x W x H)
  • Weight : 472 g
  • Casing material : Plastic
Protections
  • Over temperature, Overload, Short-circuit, Reversible

Specifications

Sorry, currently do not have any product specifications
Sorry, currently do not have any video uploaded.