MEANWELL 50W SINGLE OUTPUT SWITCHING POWER SUPPLY - LRS-50 SERIES - LRS-50-15
View Details
Quantity: In Stock
Selected variant:
MEANWELL 50W SINGLE OUTPUT SWITCHING POWER SUPPLY - LRS-50 SERIES - LRS-50-15
Selected variant:
MEANWELL 50W SINGLE OUTPUT SWITCHING POWER SUPPLY - LRS-50 SERIES - LRS-50-15
-
LRS-50-15
Features
- Universal AC input/full rauge
- Withstand 300VAC surge input for 5 seconds
- No load power consumption <0.3W
- Miniature sizw and 1 U low profile
- High operating temperature up to 70°C
- Protections: Short circuit / Overload / Over voltage
- Cooling by free air convection
- Compliance to IEC/BS EN/EN 60335-1(PD3) and IEC/BS EN/EN61558-1, -2-16 for housebold appliances
- Operating altitude up to 5000 meters
- Withstand 5G vibration test
- High efficiency, long life and high reliabaility
- LED indicator for power on
- Over voltage category III
- 100% full load burn-in test
- 3 years warranty
Applications
- Industrial automation machinery
- Industrial control system
- Mechanicala and electrical equipment
- Electronic instruments, equipments or apparatus
- Household appliances
GTIN CODE
Description
Description
- LRS-50 series is a 50W single-output enclosed type power supply with 30mm of low profile design. Adopting the full range 85~264VAC inout, the entire series provides an output voltage line of 3.3V, 5V, 12V -, 15V, 24V, 36V and 48V.
- In addition to the high efficiency up to 90%, the design of metallic mesh case enhances the heat dissiptaipn of LRS-50 that the whole series operates from -30°C through 70°C under air convection without a fan. Delivering an extremely low no load power consumption (less than 0.2W), it allows the end system to easily meet the worlwide energy requirement. LRS-50 has the complete protection functions and 5G anti-vibration capability; it is complied with the international safety regulations such as TUV BS EN/EN62368-1, BS EN/EN60335-1, BS EN/EN61558-1/-2-16, UL62368-1 and GB4943. LRS-50 series serves as a high price-to-performance power supply solution for various industrial applications.
SPECIFICATION
- Model : LRS-50-15
Output
- DC voltage : 15V
- Rated current : 3.4A
- Current range : 0 ~ 3.4A
- Rated power : 51W
- Ripple & noise (max) : 120mVp-p
- Voltage adj. range : 13.5 ~ 18V
- Voltage tolerance : ±1.0%
- Line regulation : ±0.5%
- Load regulation : ±0.5%
- Setup, Rise time : 1000ms, 30ms/230VAC 2000ms,30ms/115VAC at full load
- Hold up time : 30ms/230VAC 12ms/115VAC at full load
Input
- Voltage range : 85 ~ 264VAC 120 ~ 373VDC
- Frequency range : 47 ~ 63Hz
- EFFICIENCY (Typ.) : 88%
- AC current : 12V : 0.95A/115VAC 0.56A/230VAC
- Inrush current : COLD START 45A/230VAC
- Leakage current : <0.75mA / 240VAC
Protection
- Over load : 110 ~ 150% rated output power / Protection type : Hiccup mode, recovers automatically after fault condition is removed
- Over voltage : 18.75 ~ 25.75V / Protection type : Shut down o/p voltage, re-power on to recover
Environment
- Working temp. : -30 ~ +57℃ (Refer to ''Derating Curve'')
- Working humidity : 20 ~ 90% RH non-condensing
- Storage temp. humidity : -40 ~ +85℃, 10 ~ 95% RH
- Temp. coefficient : ±0.03%/℃ (0 ~ 50℃)
- Vibration : 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
- Over voltage category : Ⅲ; Compliance to BS EN/EN61558, BS EN/EN50178, BS EN/EN60664-1, BS EN/EN62477-1; altitude up to 2000 meters
Safety & EMC
- Safety standards : UL62368-1, TUV BS EN/EN62368-1, BS EN/EN60335-1, BS EN/EN61558-1/-2-16,CCC GB4943.1, BSMI CNS15598-1, EAC TP TC 004, AS/NZS 60950.1(by CB),KC K60950-1(for LRS-50-12/24 only), BIS IS13252(Part1): 2010/IEC 60950-1: 2005(except for LRS-50-48) approved
- Withstand voltage : I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC
- Isolation resistance : I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC emission : Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN55014, BS EN/EN61000-3-2,-3, GB/T 9254, BSMI CNS15936, EAC TP TC 020,KC KN32,KN35(for LRS-50-12/24 only)
- EMC immunity : Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61000-6-2 (BS EN/EN50082-2),BS EN/EN55035, heavy industry level, EAC TP TC 020,KC KN32,KN35(for LRS-50-12/24 only)
Others
- MTBF : 3149.8K hrs min. Telcordia SR-332 (Bellcore) ; 561.6Khrs min. MIL-HDBK-217F (25℃)
- Dimension : 99*82*30mm (L*W*H)
- Packing : 0.23Kg; 60pcs/14.8Kg/0.88CUFT
Specifications
Sorry, currently do not have any video uploaded.