MEANWELL 100W SINGLE OUTPUT LED POWER SUPPLY - LPC-100 SERIES - LPC-100-500

MEANWELL 100W SINGLE OUTPUT LED POWER SUPPLY - LPC-100 SERIES - LPC-100-500

  • LPC-100-500

Features
  • Constant current design
  • Universal AC input/full rauge
  • Withstand 300VAC surge input for 5 seconds
  • High efficiency up to 90%
  • Protections: Short circuit / Over voltage
  • Cooling by free air convection
  • Fully encapsulated with IP67 level 
  • Fully isolated plastic case
  • Class II power unit, no FG
  • 100% full load burn-in test
  • Low cost, high reliabaility
  • 2 years warranty 
Applications
  • Suitable for LED related fixture or appliance (such as LED Decoration or Advertisement devices)
GTIN CODE

Description
  • LPC-100 series is one 100W single output AC/DC LED switching power supple. It features the constant current design, providing various models with the output current ranging from 350mA through 2100mA the LED lighting applications employ the most frequently.
  • LPC-100 operates for the range 90~264VAC so it can perfectly work for most of the countries in the world. The whole series is based on class II (without FG pin) design, housed with a 94V-0 flame retardant plastic case. With the working efficiency up to 90%, LPC-100 can work at the ambient temperature between -25°C~+50°C under air convection.

SPECIFICATION
  • Model : LPC-100-500
Output 
  • Rated current : 500mA
  • Current accuracy : ±5.0%
  • Constant current region : 100 ~ 200V
  • Rated power : 100W
  • Ripple current : ±5%
  • Ripple & noise : 1.5Vp-p
  • Line regulation : ±1%
  • Voltage tolerance : ±1.5%
  • Setup, Rise time : 1000ms, 80ms / 230VAC 2000ms,80ms/115VAC at full load
  • Hold up time : 16ms/230VAC 10ms/115vac at full load
Input
  • Voltage range : 90 ~ 264VAC 127VDC ~ 370VDC
  • Frequency range : 47 ~ 63Hz
  • EFFICIENCY (Typ.) : 90%
  • AC current : 12V : 2.2 A / 115VAC 1.2A / 230VAC
  • Inrush current : COLD START 35A(twidth=1800 s measured at 50% Ipeak) at 230VAC; Per NEMA 410
  • Max. No. of PSUs on 16A circuit breaker : 1 units (circuit breaker of type B) / 2 units (circuit breaker of type C) at 230VAC
  • Leakage current : <0.25mA / 240VAC
Protection
  • Short circuit : Hiccup mode, recovers automatically after fault condition is removed
  • Over voltage : 220 ~ 240V / Protection type : Shut down and latch off o/p voltage re-power on to recovery
Environment
  • Working temp. : -25 ~ +50℃ (Refer to ''Derating Curve'')
  • Working humidity : 10 ~ 95% RH non-condensing
  • Storage temp. humidity : -40 ~ +80℃, 10 ~ 95% RH
  • Temp. coefficient : ±0.03%/℃ (0 ~ 50℃)
  • Vibration : 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
Safety & EMC
  • Safety standards :  IEC/EN 62368-1;EAC TP TC 004, IP67 approved,
  • Withstand voltage : I/P-O/P:3KVAC
  • Isolation resistance : I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
  • EMC emission : Compliance to EN55032(CISPR32) Class B; EN61000-3-2 Class A(≦80% load); EN61000-3-3, EAC TP TC 020
  • EMC immunity : Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level , criteria A, EAC TP TC 020
Others
  • MTBF : 511Khrs min. MIL-HDBK-217F (25℃)
  • Dimension : 190*52*37mm (L*W*H)
  • Packing : 0.61Kg;20pcs/13.2Kg/0.55CUFT