MEANWELL 60W SINGLE OUTPUT SWITCHING POWER SUPPLY - HLG-60H SERIES - HLG-60H-30
View Details
Quantity: In Stock
Selected variant:
MEANWELL 60W SINGLE OUTPUT SWITCHING POWER SUPPLY - HLG-60H SERIES - HLG-60H-30
Selected variant:
MEANWELL 60W SINGLE OUTPUT SWITCHING POWER SUPPLY - HLG-60H SERIES - HLG-60H-30
-
HLG-60H-30
- Universal AC input / Full range (up to 305VAC)
- Built-in active pfc function
- Protections: Short circuit / Over current / Over voltage / Over temperature
- Cooling by free air convection
- OCP point adjustable through output cable or internal potentiometer
- IP67 / IP65 design for indoor or outdoor installations
- Class 2 power unit
- Three in one dimming funvtion (1~10Vdc or PWM signal or resistance)
- Suitable for LED lighting and moving sign applications
- Compliance to worldwide safety regulations for lighting
- SUitable for dry / damp / wet locations
- 5 years warranty (Note. 10)
SPECIFICATION
- Model : HLG-60H-30
- DC voltage : 30V
- Constant current region : 18 ~ 30V
- Rated current : 2A
- Rated power : 60W
- Ripple & noise (max.) : 200mVp-p
- Volatge adj. range : 27 ~ 33V
- Current adj. range : Can be adjusted by internal potentiometer A type only / 1.2 ~ 2A
- Voltage tolerance : ±1.0%
- Line regulation : ±0.5%
- Load regulation : ±0.5%
- Setup, rise time : 500ms, 80 ms at full load 230VAC/115VAC
- Hold up time(typ.) : 16ms/230VAC 16ms/115VAC at full load
- Voltage range : 90 ~ 305VAC 127 ~ 431VDC
- Frequency range : 47 ~ 63Hz
- Power factor : PF > 0.98/115VAC, PF > 0.95/230VAC, PF > 0.92/277VAC @ full load
- Total harmonic distortion : THD < 20% when output loading ≧ 60%/115VAC/230VAC input and output loading ≧75%/277VAC input
- Efficiency : 90%
- AC current : 0.64AA/115VAC / 0.32A/230VAC / 0.3A/277VAC
- Inrush current : Cold start 55A (width=265 μs measured at 50% peak)/230VAC
- Leakage current : <0.75mA / 277VAC
- Over current : 95 ~ 108% / Protection type : Constant current limiting, recovers automatically after fault condition is removed
- Short circuit : Hiccup mode, recovers automatically after fault condition is removed
- Over voltage : 35 ~ 43V / Shut down o/p voltage, re-power on to recover
- Over temperature : Shut down o/p voltage, re-power on to recover
- Working temp. : -40 ~ +770°C
- Working humidity : 20 ~ 95% RH non-condensing
- Storage temp. humidity : -40 ~ +80°C, 10 ~ 95% RH
- Temp. coefficient : ± 0.03%/ °C (0~60°C)
- Vibration : 10 ~ 500Hz, 5G 12min,/1 cycle, period for 72min. each along X, Y, Z axes
- Safety standards : UL8750, CSA C22.2 No. 250.0-08 (except for 48V, 54V), EN61347-1, EN61347-2-13 independent, IP65 or IP67, J61347-1, J61347-2-13 approved ; design refer to UL60950-1, TUV EN60950-1, EN60335-1
- Withstand voltage : I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- Isolation resistance : I/P-O/P,I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C / 70% RH
- EMC emission : Compliance to EN55015, EN61000-3-2 Class C ( 60% load) ; EN61000-3-3
- EMC immunity : Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge 4KV), criteria A
- MTBF : 338K hrs min. MIL-HDBK-217F (25 )
- Dimension : 171*61.5*36.8mm (L*W*H)
- Packing : 0.73Kg; 20pcs/15.6Kg/0.9CUFT